Fanavar Bargh Golestan Co
.Ltd
Import & Supply Explosion Proof Equipment
Home
About us
Products
Communication
Telephone
EX-Proof
Industrial
W/P Call Station
Acostic hood
Ex signaling & audible
Ex loudspeaker
Ex proof mobile phone
Paging system
Electrical
EX Lighting Fixture
EX Floodlight
Ex Portable Floodlight
Ex Proof LED Light
Mobile Dist. Unit & Heater
Ex Local Control Station
EX Socket & Plug
Ex Junction Box
Ex Earthing System
Ex Electromotor
Ex-proof Fan
Ex-proof Electronic ballast
Ex Limit Switch
Ex Panel
Ex/Wp Cable Gland
EX-Proof
Industrial
Ex Fitting
Hand lamp & Torches
Atex Lights
Instrument
Actuator&Valve positioner
Detectors
Transmitter
Thermostat
Other
Clients
Projects
ATEX CERT
J.AUER
CORTEM
MICA
News
Contact us
Products
»
Instrument
» Transmitter
Pressure Transmitter (Type IS-20, IS-20-F Intrinsically Safe)
✓
Signal output: 4-20 mA 2-wire
✓
Supply voltage: 10-30 VDC
✓
Process connection: 1/2 NPT Male
✓
Electrical connection: DIN EN 175301-803 (DIN 43 650) with 1/2 NPT female conduit plug connector
✓
Pressure ranges from 50 InWC to 15,000 psi
✓
FM, CSA approval for:
✓
Intrinsically safe Class I, II and III Division 1, Group A, B, C, D, E, F, G
✓
Dust Class II and III Division 1, Group E, F, G
✓
Class I, Zone 0, AExia II C
✓
Ex- protection EExia I/II C T6 according to ATEX for:
✓
Gases, vapors and mist: Connection to Zone 0, Zone 1 and Zone 2
✓
Dust: Connection to Zone 20, Zone 21 and Zone 22
✓
Mining: Category M1 and M2
✓
Suitable for SIL 2 according to IEC 61508 / IEC 61511
✓
manufacturer:WIKA
Diaphragm Pressure Transmitter (Type IS-21 Intrinsically Safe Flush)
✓
Signal output: 4-20 mA 2-wire
✓
Supply voltage: 10-30 DC
✓
Process connection: G1B or G1/2B depending upon pressure
✓
Electrical connection: DIN EN 175301-803 (DIN 43 650) with 1/2
✓
Pressure ranges from 50 InWC to 15,000 psi
✓
FM, CSA approval for:
✓
Intrinsically safe Class I, II and III Division 1, Group A, B, C, D, E, F, G
✓
Dust Class II and III Division 1, Group E, F, G
✓
Class I, Zone 0, AExia II C
✓
Ex- protection EExia I/II C T6 according to ATEX for:
✓
Gases, vapors and mist: Connection to Zone 0, Zone 1 and Zone 2
✓
Dust: Connection to Zone 20, Zone 21 and Zone 22
✓
Mining: Category M1 and M2
✓
Suitable for SIL 2 according to IEC 61508 / IEC 61511
✓
manufacturer:WIKA
Pressure Transmitter (Type E-10 Explosion-proof)
✓
Vacuum to 15,000 psi
✓
Signal output: 4-20mA, 2-wire or 1-5 V 3-wire low power
✓
Supply voltage: 10-30 VDC or 6-30 VDC
✓
(low power version)
✓
Process connection: 1/4
✓
Electrical connection: 1/2
✓
FM-approved explosion-proof for Class I
✓
Division 1 hazardous locations
✓
Available with 4 ... 20 mA, 2-wire or 1 ... 5 V, 3-wire low power output signals
✓
Engineered to withstand harsh environments
✓
NACE MR0175 compliant wetted parts
✓
Retrofits many existing oil and gas applications
✓
manufacturer:WIKA
Pressure Transmitter (Type E-11 Explosion-proof Flush Diaphragm)
✓
Vacuum to 5,000 psi
✓
Signal output: 4-20mA, 2-wire or 1-5 V 3-wire low power
✓
Supply voltage: 10-30 VDC or 6-30 VDC (low power version)
✓
Process connection: Non-clogging flush diaphragm G1B or G1/2B (depending on pressure range)
✓
Electrical connection: 1/2
✓
FM-approved explosion-proof for Class I
✓
Division 1 hazardous locations
✓
Available with 4 ... 20 mA, 2-wire or 1 ... 5 V, 3-wire low power output signals
✓
Engineered to withstand harsh environments
✓
NACE MR0175 compliant wetted parts
✓
Retrofits many existing oil and gas applications
✓
manufacturer:WIKA
Type N-10 Hazardous Area Non-incendive Transmitter
✓
FM approved non-incendive for Class I Division 2 hazardous locations
✓
Engineered to meet the harsh demands of gas compressor applications
✓
Does not require the use of intrinsically safe barriers
✓
NACE MR-01-75 compliant wetted parts
✓
4-20 mA or low power 1-5 volt output signals available
✓
Signal output: 4-20 mA 2-wire or 1-5 V 3-wire
✓
Supply voltage: 10-30 DC (6-30 VDC for 1-5 V version)
✓
Process connection: 1/4 NPT Male
✓
Electrical connection: 1/2
✓
Vacuum to 15,000 psi
✓
manufacturer:WIKA
Pressure Transmitter (Type N-11 Non-incendive Flush Diaphragm)
✓
FM approved non-incendive for Class I Division 2 hazardous locations
✓
Engineered to meet the harsh demands of gas compressor applications
✓
Does not require the use of intrinsically safe barriers
✓
NACE MR-01-75 compliant wetted parts
✓
4-20 mA or low power 1-5 volt output signals available
✓
Vacuum to 5,000 psi
✓
Signal output: 4-20 mA 2-wire or 1-5 V 3-wire
✓
Supply voltage: 10-30 DC (6-30 VDC for 1-5 V version)
✓
Process connection: G1B or G1/2B flush diaphragm depending on pressure range
✓
Electrical connection: 1/2
✓
manufacturer:WIKA
1
2
Next
Pressure Transmitter (Type IS-20, IS-20-F Intrinsically Safe)
Diaphragm Pressure Transmitter (Type IS-21 Intrinsically Safe Flush)
Pressure Transmitter (Type E-10 Explosion-proof)
Pressure Transmitter (Type E-11 Explosion-proof Flush Diaphragm)
Type N-10 Hazardous Area Non-incendive Transmitter
Pressure Transmitter (Type N-11 Non-incendive Flush Diaphragm)