Products » Communication » Telephone

Explosion-proof Telephone dST (Ex ResisTeL - zone 1)

Explosion-proof Telephone dST (Ex ResisTeL - zone 1)
  • Ex II 2 G Ex emb [ib] IIC T5/T6
  • Ex II 2 D Ex tD A21 IP66 T100 °C/T80 °C
  • -25 °C ≤ Ta ≤ +60 °C/+40°C
  • Zone 1, 2, 21, 22
  • Explosion-proof telephone for universal applications in the industry (onshore and offshore)
  • Certified for gas and dust explosion endangered areas (G and D)
  • Resistant against high temperature differences, humidity, seawater, acids, alkalis etc
  • Very robust impact protected telephone housing (impact protection IK 09)
  • Freely programmable, well readable alphanumerical display
  • Designed for use with gloves, V4A stainless steel keypad – 21 keys
  • Model without keypad available as emergency telephone
  • Comfort telephone functions as in office communiction
  • Handsfree operation
  • Visual call signalling on display
  • Ringing sound pressure level approx. 90 dB (A) in 1 m
  • 10 ringing tone melodies selectable
  • Listening by loudspeaker: max. 68 dB (A) in 1 m
  • Receiver volume adjustable in 7 steps from 0 dB to +12 dB
  • Menu in german/english/french/spanish
  • Telephone directory – max. 50 entries (names and numbers)
  • Locking option via PIN-code
  • manufacturer:Auer Signal - Austria
Download attached file

Explosion-Proof Telephone dFT3 (FernTel 3 – zone 2)

Explosion-Proof Telephone dFT3 (FernTel 3 – zone 2)
  • Ex II 3G Ex nAnL IIC T5
  • Ex II 3D Ex tD A22 IP65 T80 °C
  • Zone 2, 22
  • well designed, analogue telephone for use in explosion endangered atmospheres of zone 2 and 22
  • for use in areas in which explosion endangered atmospheres can develop due to manufacturing reasons (e.g. in chemical and petrochemincal industries due to gases, vapours, sprays etc.)
  • housing made of polycarbonate, stainless steel screws
  • housing colours yellow, red, grey or black
  • can be used as desk or wall telephone
  • models with or without display
  • option: receiver can be firmly fixed – stabilizer bracket
  • call tone approx. 95 dB (A) in 1 m
  • ATEX certified
  • Ex ResisTeL Zone 2
  • manufacturer:Auer Signal - Austria
Download attached file

Explosion-Proof analogue Telephone dST-MB(zone 1,2)

Explosion-Proof analogue Telephone dST-MB(zone 1,2)
  • Ex II 2 G Ex e mb [ib] IIC T6/T5 Gb,Ex II 2 D tb [ib] IIIC T80°C/T100 °C Db IP66
  • ambienet temperature: -25°C TO +40°C(T6),-25°C TO +60°C(T5)
  • Explosion-proof analogue telephone for universal applications in the industry (onshore and offshore)
  • Certified for gas and dust explosion endangered areas (G and D)
  • Resistant against high temperature differences, humidity, seawater, acids, alkalis, etc.
  • Very robust impact protected telephone housing (impact protection IK 09)
  • Designed for use with gloves, V4A stainless steel keypad – 21 keys
  • 3 memory buttons - allow quick access to freely programmable individual emergency/call numbers
  • Comfort telephone functions as in office communiction
  • Ringing sound pressure level approx. 90 dB (A) in 1 m
  • Combinable accessories see page 94/95
  • manufacturer:Auer Signal - Austria
Download attached file

Ex Robustel

Ex Robustel
  • Explosion-proof telephones
  • 3 direct memories
  • Ring loudness 90 dB (3 levels)
  • Pulse and tone dialling
  • FLASH (adjust. to 100 or 200 ms)
  • Optical signal by LED diode
  • Analog telephone line
  • 5 various ring tones
  • Pause (adjustable to 1 or 3 sec)
  • Electronic key lock
  • Ambient temperature: - 25 °C to + 60 °C
  • Protection: IP 66
  • Dimensions: 245 x 225 x 129 mm (h x w x d)
  • Weight: 3,2 kg
  • manufacturer: A2S

EXPLOSION - PROOF TELEPHONE ATEX (TLA227A)

EXPLOSION - PROOF TELEPHONE ATEX (TLA227A)
  • Cast aluminium casing. Sealed by tightening 3 fixing screws.
  • Ex II 2 GD Ex em(ib) IIC T5/ IP66
  • Certificate: 03 ATEX 0118X
  • Shockproof, dual-operation pulse or DTMF dialling, 14 buttons.
  • Weatherproof ringer > 92dB/1 meter.
  • Cast aluminium handset with Teflon finish, equipped with stainless-steel armoured cord with resistance greater than 200 Kg.
  • Electronic circuit with adjustable amplification system and dual connectors, detachable and lockable.
  • 8 numbers in memory.
  • Test controlled distance of good functioning of the phone.
  • Can be installed at 7-16kmdistance from PABX without any amplificatory.
  • Second cable entry to add signalization or head phones set.
  • Max. / min. amb. Temp: -40 °C / + 60°
  • dimensions: 210 x 240 x 117 m.
  • weight: 4,5 kg
  • manufacturer: lelas-france
Download attached file

EXPLOSION - PROOF TELEPHONE ATEX(TLA229A)

EXPLOSION - PROOF TELEPHONE ATEX(TLA229A)
  • Remote diagnostic
  • Reinforced composite
  • Flashing light
  • Ex II 2 GD Ex em[ib] ib IIC T5/IP66
  • Optional equipment: voip equipment / headset equipment
  • Loudspeaker (hands-free)/microphone: vandal resistant/5W mounting: on wall Open the pivoting front panel removing the three screws.
  • Pass the cables through the cable glands being sure that the cable fit with the rubber gasket
  • Connect the telephone wires at the screw terminals as indicated in the operator’s book
  • Make a functional test calling another extension and asking to be re-called
  • Adjust the volume of the bell (see operator’s book)
  • Adjust the sensitivity of the microphone (see operator’s book)
  • Close the front panel paying attention to the position of the gaskets
  • Maintenance: all circuits and control devices are fixed on the easy removable front plate for a very quick substitution of equipment in field.
  • Dimensions: 201 x 320 x 113 mm
  • weight: 2,3kg
  • manufacturer: lelas-france