Fanavar Bargh Golestan Co
.Ltd
Import & Supply Explosion Proof Equipment
Home
About us
Products
Communication
Telephone
EX-Proof
Industrial
W/P Call Station
Acostic hood
Ex signaling & audible
Ex loudspeaker
Ex proof mobile phone
Paging system
Electrical
EX Lighting Fixture
EX Floodlight
Ex Portable Floodlight
Ex Proof LED Light
Mobile Dist. Unit & Heater
Ex Local Control Station
EX Socket & Plug
Ex Junction Box
Ex Earthing System
Ex Electromotor
Ex-proof Fan
Ex-proof Electronic ballast
Ex Limit Switch
Ex Panel
Ex/Wp Cable Gland
EX-Proof
Industrial
Ex Fitting
Hand lamp & Torches
Atex Lights
Instrument
Actuator&Valve positioner
Detectors
Transmitter
Thermostat
Other
Clients
Projects
ATEX CERT
J.AUER
CORTEM
MICA
News
Contact us
Products
»
Electrical
» Ex Earthing System
Electronic grounding system (GRD 4200)
✓
Ex protection: Ex II 2(1) GD Ex d [ia] ia IIB + H2 T6 Ex tD [ia D] A21
✓
Certificate: CESI 04 ATEX 129
✓
Installation: zona1 - 2 - 21 - 22
✓
Body and cover in low copper content aluminium alloy
✓
Stainless steel cover bolts
✓
Internal/external earth screw
✓
Fixing lugs
✓
Connecting clamp complete with 8 meters of cable
✓
Selector insertion, red ‘stop’ light and green ‘go’ light
✓
Internal electronic earthing system
✓
Nickel-plated brass cable gland
✓
Ral 7035 epoxy coating
✓
manufacturer: cortem group-italy
Download attached file
Grounding clamp (PMT...)
✓
Ex II 2 GD Ex d IIC T6 - Ex A21 IP 65/66
✓
CESI 03 ATEX 201
✓
zone 1 - 2 - 21 - 22
✓
Body covered in nylon
✓
External contact elements in phosphor bronze
✓
Interiors in brass
✓
Nickel-plated brass cable gland
✓
manufacturer:cortem group-italy
Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071(zone 1,2,21,22)
✓
Monitored electrostatic grounding of tank containers and drums during loading
✓
Continuous monitoring of correct grounding
✓
Robust design
✓
Weather-protected plastic enclosure (IP66) or stainless steal enclosure (IP66)
✓
Easy installation and operation
✓
Potential-free contact for signalling to the process control system and external control devices
✓
Insulated point of suspension
✓
For use up to SIL 2 (IEC 61508)
✓
Ex II 2 G Ex d e [ia] IIC T4/Ex II 2 D Ex tD A21 IP66 T80°C-Version 8125/5071
✓
Certificate:PTB 00 ATEX 3116
✓
Ex II 2 G Ex d e [ia] IIC T4/E II 2 D Ex tD A21 IP66 T80°C-Version:8146/5075
✓
Certificate:PTB 01 ATEX 1024
✓
Rated voltage 120 / 230 V
✓
Rated current 50 mA
✓
Power consumption 3 VA
✓
manufacturer: stahl-germany
Download attached file
Ground Monitoring Device Series 8485(zone 1,2)
✓
Controlled electrostatic grounding of road tankers and rail cars during loading
✓
Continuous monitoring of correct grounding
✓
The object recognition prevents potential operator errors (with road tankers)
✓
Water jet protected aluminium enclosure IP65
✓
Two potential-free change-over contacts per channel for signalling
✓
Insulated point of suspension for clamps
✓
Ambient temperature - 50 ... + 60 ° C
✓
Ex II 2 G Ex d [ib] IIB T4
✓
Certificate: FTZÚ 09 ATEX 0059X
✓
Rated voltage 230 +/- 10 % V AC
✓
Rated current 50 mA
✓
Power consumption 10 VA
✓
manufacturer: stahl-germany
Download attached file
Ground Monitoring Device Series 7485(zone 2.21,22)
✓
Controlled electrostatic grounding of road tankers and rail cars during loading
✓
Continuous monitoring of correct grounding
✓
The object recognition prevents potential operator errors (with road tankers)
✓
Water jet protected stainless steel enclosure IP65
✓
Easy installation and operation
✓
Two potential-free change-over contacts per channel for signalling
✓
Ex II 3 (2) G Ex nAC ib [ib] IIC T4- Ex II 2 D Ex tD A21 T62°C IP65
✓
Certificate: FTZÚ 10 ATEX 0068
✓
Rated voltage 230 +/- 10 % V AC
✓
Rated current 50 mA
✓
Power consumption 10 VA
✓
Ambient temperature: Operating temperature - 20 ... + 40 °C/ Storage temperature - 20 ... + 40 °C
✓
manufacturer: stahl-germany
Download attached file
Electronic grounding system (GRD 4200)
- ✓ Ex protection: Ex II 2(1) GD Ex d [ia] ia IIB + H2 T6 Ex tD [ia D] A21
- ✓ Certificate: CESI 04 ATEX 129
- ✓ Installation: zona1 - 2 - 21 - 22
- ✓ Body and cover in low copper content aluminium alloy
- ✓ Stainless steel cover bolts
- ✓ Internal/external earth screw
- ✓ Fixing lugs
- ✓ Connecting clamp complete with 8 meters of cable
- ✓ Selector insertion, red ‘stop’ light and green ‘go’ light
- ✓ Internal electronic earthing system
- ✓ Nickel-plated brass cable gland
- ✓ Ral 7035 epoxy coating
- ✓ manufacturer: cortem group-italy
Download attached fileGrounding clamp (PMT...)
Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071(zone 1,2,21,22)
- ✓ Monitored electrostatic grounding of tank containers and drums during loading
- ✓ Continuous monitoring of correct grounding
- ✓ Robust design
- ✓ Weather-protected plastic enclosure (IP66) or stainless steal enclosure (IP66)
- ✓ Easy installation and operation
- ✓ Potential-free contact for signalling to the process control system and external control devices
- ✓ Insulated point of suspension
- ✓ For use up to SIL 2 (IEC 61508)
- ✓ Ex II 2 G Ex d e [ia] IIC T4/Ex II 2 D Ex tD A21 IP66 T80°C-Version 8125/5071
- ✓ Certificate:PTB 00 ATEX 3116
- ✓ Ex II 2 G Ex d e [ia] IIC T4/E II 2 D Ex tD A21 IP66 T80°C-Version:8146/5075
- ✓ Certificate:PTB 01 ATEX 1024
- ✓ Rated voltage 120 / 230 V
- ✓ Rated current 50 mA
- ✓ Power consumption 3 VA
- ✓ manufacturer: stahl-germany
Download attached fileGround Monitoring Device Series 8485(zone 1,2)
- ✓ Controlled electrostatic grounding of road tankers and rail cars during loading
- ✓ Continuous monitoring of correct grounding
- ✓ The object recognition prevents potential operator errors (with road tankers)
- ✓ Water jet protected aluminium enclosure IP65
- ✓ Two potential-free change-over contacts per channel for signalling
- ✓ Insulated point of suspension for clamps
- ✓ Ambient temperature - 50 ... + 60 ° C
- ✓ Ex II 2 G Ex d [ib] IIB T4
- ✓ Certificate: FTZÚ 09 ATEX 0059X
- ✓ Rated voltage 230 +/- 10 % V AC
- ✓ Rated current 50 mA
- ✓ Power consumption 10 VA
- ✓ manufacturer: stahl-germany
Download attached fileGround Monitoring Device Series 7485(zone 2.21,22)
- ✓ Controlled electrostatic grounding of road tankers and rail cars during loading
- ✓ Continuous monitoring of correct grounding
- ✓ The object recognition prevents potential operator errors (with road tankers)
- ✓ Water jet protected stainless steel enclosure IP65
- ✓ Easy installation and operation
- ✓ Two potential-free change-over contacts per channel for signalling
- ✓ Ex II 3 (2) G Ex nAC ib [ib] IIC T4- Ex II 2 D Ex tD A21 T62°C IP65
- ✓ Certificate: FTZÚ 10 ATEX 0068
- ✓ Rated voltage 230 +/- 10 % V AC
- ✓ Rated current 50 mA
- ✓ Power consumption 10 VA
- ✓ Ambient temperature: Operating temperature - 20 ... + 40 °C/ Storage temperature - 20 ... + 40 °C
- ✓ manufacturer: stahl-germany
Download attached file